Steel PowerLok® 2-part lid (AS 3996 Class B)

  • AS/NZS 4586 Slip Resistance Rating R10
  • IP2XD (AS 60529) protection against ingress of foreign objects when hatch is closed.
  • Lids fit into rebate at top of pit, whilst access covers must be installed in a cast in situ concrete collar.

Steel 2-part Lid (AS 3996 Class B)

  • AS/NZS 4586 Slip Resistance Rating R10
  • IP4X (AS 60529) protection against ingress of foreign objects if fitted with universal plug.
  • Lids fit into rebate at top of pit, whilst access covers must be installed in a cast in situ concrete collar.

Cement Concrete 2-part Lid (AS 3996 Class A)

  • AS/NZS 4586 Slip Resistance Rating R9.
  • IP4X (AS 60529) protection against ingress of foreign objects if fitted with universal plug.
  • Lids fit into rebate at top of pit, whilst access covers must be installed in a cast in situ concrete collar.

  • Increase pit depth, riser rebate is identical to pit rebate and with lid, offers the same IP protection.
  • Can be cut to required height. Each riser adds 300mm depth.
  • ACO recommends no more than 2 risers.
  • Recesses beneath rebate on opposite corners to fit ACO's lifting device.
  • Holesaw guides for conduit entry - holes can be cut anywhere on side walls.
  • Maximum number of holes recommended per pit is limited by conduit quantity and size.
  • Contact ACO for guidance.

All access covers have IP4X (AZ 60529) protection against ingress of foreign objects. Rhinocast® access covers offer water and gas tightness to AS 3996.

  1. Steel Urbanfil® recessed 2-part cover (AS 3996 Class B)
  2. Steel Pavermate® recessed 2-part cover (AS 3996 Class B)
  3. Steel frame - external dim. 1450 x 580 x 70mm
  4. Cast-in-situ concrete collar

  1. Ductile iron Rhinocast® solid top 2-part cover (AS 3996 Class B) AS/NZS 4586 Slip Resistance Rating R10
  2. Ductile iron Rhinocast® recessed 2-part cover (AS 3996 Class B)
  3. Iron frame - external dim. 1355 x 600 x 55mm
  4. Cast-in-situ concrete collar
  5. Ductile iron Rhinocast® solid top 2-part cover (AS 3996 Class D) AS/NZS 4586 Slip Resistance Rating R10
  6. Ductile iron Rhinocast® recessed 2-part cover (AS 3996 Class D or G)
  7. Iron frame - Class D external dim. - 1485 x 665 x 100mm Class G external dim. - 1525 x 835 x 125mm
  8. Cast-in-situ concrete collar
DescriptionPart No.Weight (kg)
Type 8 Polymer Concrete Pit74991162
Type 8 Polymer Concrete Riser (adds 300mm to pit depth)7341985

Lids & CoversPart No.Cover Wt (kg)¹Total Wt (kg)
Cement Concrete 2-part Lid (AS 3996 Class A) - Blank²750103369
Cement Concrete 2-part Concrete Lid (AS 3996 Class A) - Communications²750113369
Cement Concrete 2-part Concrete Lid (AS 3996 Class A) - Electricity²750123369
Steel 2-part Lid (AS 3996 Class B)768201531
Steel PowerLok® 2-part Lid (AS 3996 Class B)²768302039
Steel Urbanfil® recessed 2-part cover (AS 3996 Class B)³825671339
Steel Pavermate® recessed 2-part cover (AS 3996 Class B)³823731541
Ductile Iron Rhinocast® recessed 2-part cover (AS 3996 Class B)*854333091
Ductile Iron Rhinocast® solid top 2-part cover (AS 3996 Class B)*868532889
Ductile Iron Rhinocast® recessed 2-part cover (AS 3996 Class D)*8943151182
Ductile Iron Rhinocast® solid top 2-part cover (AS 3996 Class D)*8085551169
Ductile Iron Rhinocast® recessed 2-part cover (AS 3996 Class G)*87463135358

Notes:

  1. Lid and access cover weights are provided as lifting weight (individual cover parts) and total weight. Recessed cover weights do not included pavement infill; for approx. lifting weight - Urbanfil®/Pavermate® covers - multiply weight by 7; Rhinocast® covers multiply weight by 1.5.
  2. All lids are supplied with brackets and support bars where applicable. PowerLok® lids supplied with locking bold (padlock not supplied).
  3. Optional brass edging (Specify 'BE' after part number).
  4. Optional locking, brass or stainless steel edging in 12mm or 40mm heights (Specify 'BE' or 'SS' and height after part number).
Internal Working Area(mm)
A1168
B358
X1251
Y441
Z830
Overall Dimensions (mm)
L1351
W541
D902

Notes:

  1. Using risers will increase pit depth (Z & D) by depth of riser.
  2. Access covers will increase depth of pit by height of concrete collar - allowance should be made for concrete collar during pit installation.